Business Description:
Categories
plumbing, heating, and cooling
Maintenance Performed
Maintenance was performed on my mulizone gas boiler heating system. He raised the pressure, bled the lines and emptied the expansion tank. Unfortunately he missed the fact that one of the three motor heads wasn’t working. Because the other zones were working, hot water was still being produced and entered the non-working zone, but to a much lesser extent. Rather than call the tech back, I replaced the motor head myself.